A-037 Comparative Performance of Three Troponin Assays for Cardiac Monitoring in Spinal Muscular Atrophy (SMA) and Duchene Muscular Atrophy (DMD) Gene Therapy Patients

You are here: Home → Topics → Article 52428

Evidence Card

Field Value
Discovery Selected by deterministic topic screening; not scientific acceptance.
Evidence status Discovery candidate
Topic(s) Neuroscience Biomarkers
Next step Wait for deterministic selection into an evidence batch.
Source Open publisher page
Published 2026-10-04
Reviewed evidence No published Reviewed Study

Discovery status

Selected by deterministic topic screening. This discovery record is retained independently of the scientific evidence decision.

Evidence status

No published reviewed-study page exists for this article.

Source

Field Value
Original article Open publisher page
Journal Clinical Chemistry
Published 2026-10-04
Radar first seen 2026-10-04
Radar article ID 52428

Access availability

Field Value
DOI 10.1093/clinchem/hvag086.031
Status full_text_link_unverified
Available copy Open available copy
Host type publisher
License https://academic.oup.com/pages/standard-publication-reuse-rights
Version vor
Metadata source crossref
Checked 2026-10-12T07:59:26+00:00

Why it was selected

Neuroscience Biomarkers

Status — Discovery candidate: Awaiting bounded evidence analysis. This is not accepted evidence.

  • Screening score: 13
  • Next safe step: Wait for deterministic selection into an evidence batch.
  • Matching signals:
  • indication: Duchenne, Duchenne muscular dystrophy
  • biomarker: dystrophin
  • modality: gene therapy, gene replacement

Feed summary

Abstract Background Cardiac troponin I (c TNI) is used to monitor cardiac injury in patients receiving gene therapy for chromosome 5-related Spinal Muscular Atrophy (SMA) type 1 and Duchenne Muscular Dystrophy (DMD). SMA type 1, caused by SMN1 protein deficiency, affects ∼6 per 100, 000 births and leads to severe muscle weakness and reduced life expectancy ( Methods A total of ten heparinized plasma samples were collected from pediatric patients undergoing gene replacement therapy for Spinal Muscular Atrophy (N=9) or Duchenne Muscular Dystrophy (N=1). Specimens were tested using three commercially available troponin assays: i STAT c TNI point-of-care assay (Abbott Diagnostics) with a reference interval of less than 0.08 ng/mL; the Roche cobas e 801 high sensitive Troponin T (hsTnT) with a reference interval of less than 19 pg/mL, and Siemens Atellica IM 1600 high sensitive Troponin I (Tn IH) with a reference interval of equal or less than 45 pg/mL. The samples were first analyzed on the i STAT c TNI due to the low minimal volume requirement, and if the volume allowed, specimens were analyzed on the automated high sensitivity Troponin T and I assay. Because pediatric-specific reference ranges are not established for these assays, adult reference values were used for interpretation.

Results

All specimens analyzed with the i STAT c TNI assay had values below 0.08 ng/mL, which is the assay’s lowest reportable Troponin I concentration. For the Roche cobas e 801 high sensitivity Troponin T (hsTnT) assay, the median value was 43.1 pg/mL (range: 29.6–110 pg/mL). The Siemens Atellica IM 1600 high sensitivity Troponin I (Tn IH) assay had a median value of 28.4 pg/mL (range: 10.6–49.2 pg/mL). Based on each assay’s reference cut-offs, the results demonstrated 90% concordance between the i STAT c TNI and the Siemens Tn IH assays. All i STAT c TNI results were within the normal range, and all but one Tn IH result were also within normal limits. The single discordant sample showed an elevated c TNI value seven days prior to testing, which may indicate a cardiac effect that was better detected by the high sensitivity Tn IH assay. In contrast, the hsTnT assay showed moderately elevated values for all samples, with all results being above the cut-off suggesting cross reactivity of cardiac troponin T with skeletal muscle troponin isoforms present in patients with SMA and DMD.

Conclusion

The high sensitivity Troponin I assay shows strong concordance with the i STAT c TNI supporting its use as a suitable alternative for cardiac monitoring in pediatric patients undergoing gene therapy for SMA and DMD, potentially offering greater sensitivity to cardiac abnormalities than the point-of-care assay.