Enhancing Next-Generation Sequencing Sensitivity with High-Recovery Adapter Ligation and Cas9-Mediated Dimer Elimination
You are here: Home → Topics → Article 37265
Evidence Card
| Field | Value |
|---|---|
| Discovery | Selected by deterministic topic screening; not scientific acceptance. |
| Evidence status | Discovery candidate |
| Topic(s) | Target Ranking |
| Next step | Wait for deterministic selection into an evidence batch. |
| Source | Open publisher page |
| Published | 2026-06-04 |
| Reviewed evidence | No published Reviewed Study |
Discovery status
Selected by deterministic topic screening. This discovery record is retained independently of the scientific evidence decision.
Evidence status
No published reviewed-study page exists for this article.
Source
| Field | Value |
|---|---|
| Original article | Open publisher page |
| Journal | Clinical Chemistry |
| Published | 2026-06-04 |
| Radar first seen | 2026-09-22 |
| Radar article ID | 37265 |
Access availability
| Field | Value |
|---|---|
| DOI | 10.1093/clinchem/hvag052 |
| Status | full_text_link_unverified |
| Available copy | Open available copy |
| Host type | publisher |
| License | https://academic.oup.com/pages/standard-publication-reuse-rights |
| Version | vor |
| Metadata source | crossref |
| Checked | 2026-10-12T14:41:38+00:00 |
Why it was selected
Target Ranking
Status — Discovery candidate: Awaiting bounded evidence analysis. This is not accepted evidence.
- Screening score: 8
- Next safe step: Wait for deterministic selection into an evidence batch.
- Matching signals:
- perturbation: CRISPR
- results: increased, associated, rescued
Feed summary
Abstract Background Accurate detection of ultra–low-frequency variants is a major challenge in clinical liquid biopsy. In early cancer detection and minimal residual disease monitoring, Circulating tumor (ct DNA) may fall below 0.1% variant allele frequency, making sensitivity highly dependent on molecular recovery during library preparation. Losses at early steps, especially adapter ligation, permanently reduce analyzable molecules and cannot be rescued by deeper sequencing or bioinformatic refinement.
Methods
We developed Powerful Recovery and Improved Dimer Elimination (PRIDE) next-generation sequencing NGS, a library preparation strategy that increases adapter ligation efficiency and removes adapter dimers via sequence-specific Clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated protein 9 (Cas9) cleanup. PRIDE NGS is compatible with standard clinical work flows and requires no added sequencing depth or changes to downstream bioinformatic pipelines. Performance was assessed by targeted sequencing of cell-free (cf DNA) reference standards and clinical plasma samples.
Results
PRIDE NGS improved recovery and detection of low-frequency variants vs conventional preparation. In reference standards, it detected more variants at low allele frequencies, particularly below 0.1%. In clinical plasma samples, it similarly increased detection, including variants predicted to have moderate or high functional impact. These gains occurred at comparable or lower sequencing depth, indicating sensitivity improvements driven by enhanced molecular recovery.
Conclusions
By overcoming a key bottleneck in library preparation, PRIDE NGS lowers the practical detection threshold for ultra-low-frequency variants in liquid biopsy. This clinically applicable approach improves analytical sensitivity by lowering the detection limit without increasing the sequencing burden, supporting routine testing and longitudinal monitoring.